Интерфейс CompactPCI - разводка кабеля, техническая информация, описание
CompactPCI
PCI=Peripheral Component Interconnect.
CompactPCI is a version of PCI adapted for industrial and/or
embedded applications.
(at the backplane)
(at the device (card))
7x47 PIN (IEC917 and IEC1076-4-101) CONNECTOR at the backplane.
7x47 PIN (IEC917 and IEC1076-4-101) CONNECTOR at the device (card).
Pin |
Name |
Description |
Z1 |
GND |
Ground |
Z2 |
GND |
Ground |
Z3 |
GND |
Ground |
Z4 |
GND |
Ground |
Z5 |
GND |
Ground |
Z6 |
GND |
Ground |
Z7 |
GND |
Ground |
Z8 |
GND |
Ground |
Z9 |
GND |
Ground |
Z10 |
GND |
Ground |
Z11 |
GND |
Ground |
Z12 |
KEY |
Keyed (no pin) |
Z13 |
KEY |
Keyed (no pin) |
Z14 |
KEY |
Keyed (no pin) |
Z15 |
GND |
Ground |
Z16 |
GND |
Ground |
Z17 |
GND |
Ground |
Z18 |
GND |
Ground |
Z19 |
GND |
Ground |
Z20 |
GND |
Ground |
Z21 |
GND |
Ground |
Z22 |
GND |
Ground |
Z23 |
GND |
Ground |
Z24 |
GND |
Ground |
Z25 |
GND |
Ground |
Z26 |
GND |
Ground |
Z27 |
GND |
Ground |
Z28 |
GND |
Ground |
Z29 |
GND |
Ground |
Z30 |
GND |
Ground |
Z31 |
GND |
Ground |
Z32 |
GND |
Ground |
Z33 |
GND |
Ground |
Z34 |
GND |
Ground |
Z35 |
GND |
Ground |
Z36 |
GND |
Ground |
Z37 |
GND |
Ground |
Z38 |
GND |
Ground |
Z39 |
GND |
Ground |
Z40 |
GND |
Ground |
Z41 |
GND |
Ground |
Z42 |
GND |
Ground |
Z43 |
GND |
Ground |
Z44 |
GND |
Ground |
Z45 |
GND |
Ground |
Z46 |
GND |
Ground |
Z47 |
GND |
Ground |
|
|
|
A1 |
5V |
+5 VDC |
A2 |
TCK |
Test Clock |
A3 |
INTA# |
Interrupt A |
A4 |
BRSV |
Bused Reserved (don't use) |
A5 |
BRSV |
Bused Reserved (don't use) |
A6 |
REQ# |
Request PCI transfer |
A7 |
AD(30) |
Address/Data 30 |
A8 |
AD(26) |
Address/Data 26 |
A9 |
C/BE(3)# |
Command: Byte Enable |
A10 |
AD(21) |
Address/Data 21 |
A11 |
AD(18) |
Address/Data 18 |
A12 |
KEY |
Keyed (no pin) |
A13 |
KEY |
Keyed (no pin) |
A14 |
KEY |
Keyed (no pin) |
A15 |
3.3V |
+3.3 VDC |
A16 |
DEVSEL# |
Device Select |
A17 |
3.3V |
+3.3 VDC |
A18 |
SERR# |
System Error |
A19 |
3.3V |
+3.3 VDC |
A20 |
AD(12) |
Address/Data 12 |
A21 |
3.3V |
+3.3 VDC |
A22 |
AD(7) |
Address/Data 7) |
A23 |
3.3V |
+3.3 VDC |
A24 |
AD(1) |
Address/Data 1) |
A25 |
5V |
+5 VDC |
A26 |
CLK1 |
Clock ?? MHz |
A27 |
CLK2 |
Clock ?? MHz |
A28 |
CLK4 |
Clock ?? MHz |
A29 |
V(I/O) |
+3.3 VDC or +5 VDC |
A30 |
C/BE(5)# |
Command: Byte Enable |
A31 |
AD(63) |
Address/Data 63 |
A32 |
AD(59) |
Address/Data 59 |
A33 |
AD(56) |
Address/Data 56 |
A34 |
AD(52) |
Address/Data 52 |
A35 |
AD(49) |
Address/Data 49 |
A36 |
AD(45) |
Address/Data 45 |
A37 |
AD(42) |
Address/Data 42 |
A38 |
AD(38) |
Address/Data 38 |
A39 |
AD(35) |
Address/Data 35 |
A40 |
BRSV |
Bused Reserved (don't use) |
A41 |
BRSV |
Bused Reserved (don't use) |
A42 |
BRSV |
Bused Reserved (don't use) |
A43 |
USR |
User Defined |
A44 |
USR |
User Defined |
A45 |
USR |
User Defined |
A46 |
USR |
User Defined |
A47 |
USR |
User Defined |
|
|
|
B1 |
-12V |
-12 VDC |
B2 |
5V |
+5 VDC |
B3 |
INTB# |
Interrupt B |
B4 |
GND |
Ground |
B5 |
BRSV |
Bused Reserved (don't use) |
B6 |
GND |
Ground |
B7 |
AD(29) |
Address/Data 29 |
B8 |
GND |
Ground |
B9 |
IDSEL |
Initialization Device Select |
B10 |
GND |
Ground |
B11 |
AD(17) |
Address/Data 17 |
B12 |
KEY |
Keyed (no pin) |
B13 |
KEY |
Keyed (no pin) |
B14 |
KEY |
Keyed (no pin) |
B15 |
FRAME# |
Address or Data phase |
B16 |
GND |
Ground |
B17 |
SDONE |
Snoop Done |
B18 |
GND |
Ground |
B19 |
AD(15) |
Address/Data 15 |
B20 |
GND |
Ground |
B21 |
AD(9) |
Address/Data 9) |
B22 |
GND |
Ground |
B23 |
AD(4) |
Address/Data 4) |
B24 |
5V |
+5 VDC |
B25 |
REQ64# |
|
B26 |
GND |
Ground |
B27 |
CLK3 |
Clock ?? MHz |
B28 |
GND |
Ground |
B29 |
BRSV |
Bused Reserved (don't use) |
B30 |
GND |
Ground |
B31 |
AD(62) |
Address/Data 62 |
B32 |
GND |
Ground |
B33 |
AD(55) |
Address/Data 55 |
B34 |
GND |
Ground |
B35 |
AD(48) |
Address/Data 48 |
B36 |
GND |
Ground |
B37 |
AD(41) |
Address/Data 41 |
B38 |
GND |
Ground |
B39 |
AD(34) |
Address/Data 34 |
B40 |
GND |
Ground |
B41 |
BRSV |
Bused Reserved (don't use) |
B42 |
GND |
Ground |
B43 |
USR |
User Defined |
B44 |
USR |
User Defined |
B45 |
USR |
User Defined |
B46 |
USR |
User Defined |
B47 |
USR |
User Defined |
|
|
|
C1 |
TRST# |
Test Logic Reset |
C2 |
TMS |
Test Mode Select |
C3 |
INTC# |
Interrupt C |
C4 |
V(I/O) |
+3.3 VDC or +5 VDC |
C5 |
RST |
Reset |
C6 |
3.3V |
+3.3 VDC |
C7 |
AD(28) |
Address/Data 28 |
C8 |
V(I/O) |
+3.3 VDC or +5 VDC |
C9 |
AD(23) |
Address/Data 23 |
C10 |
3.3V |
+3.3 VDC |
C11 |
AD(16) |
Address/Data 16 |
C12 |
KEY |
Keyed (no pin) |
C13 |
KEY |
Keyed (no pin) |
C14 |
KEY |
Keyed (no pin) |
C15 |
IRDY# |
Initiator Ready |
C16 |
V(I/O) |
+3.3 VDC or +5 VDC |
C17 |
SBO# |
Snoop Backoff |
C18 |
3.3V |
+3.3 VDC |
C19 |
AD(14) |
Address/Data 14 |
C20 |
V(I/O) |
+3.3 VDC or +5 VDC |
C21 |
AD(8) |
Address/Data 8) |
C22 |
3.3V |
+3.3 VDC |
C23 |
AD(3) |
Address/Data 3) |
C24 |
V(I/O) |
+3.3 VDC or +5 VDC |
C25 |
BRSV |
Bused Reserved (don't use) |
C26 |
REQ1# |
Request PCI transfer |
C27 |
SYSEN# |
|
C28 |
GNT3# |
Grant |
C29 |
C/BE(7) |
Command: Byte Enable |
C30 |
V(I/O) |
+3.3 VDC or +5 VDC |
C31 |
AD(61) |
Address/Data 61 |
C32 |
V(I/O) |
+3.3 VDC or +5 VDC |
C33 |
AD(54) |
Address/Data 54 |
C34 |
V(I/O) |
+3.3 VDC or +5 VDC |
C35 |
AD(47) |
Address/Data 47 |
C36 |
V(I/O) |
+3.3 VDC or +5 VDC |
C37 |
AD(40) |
Address/Data 40 |
C38 |
V(I/O) |
+3.3 VDC or +5 VDC |
C39 |
AD(33) |
Address/Data 33 |
C40 |
FAL# |
Power Supply Status FAL (CompactPCI specific) |
C41 |
DEG# |
Power Supply Status DEG (CompactPCI specific) |
C42 |
PRST# |
Push Button Reset (CompactPCI specific) |
C43 |
USR |
User Defined |
C44 |
USR |
User Defined |
C45 |
USR |
User Defined |
C46 |
USR |
User Defined |
C47 |
USR |
User Defined |
|
|
|
D1 |
+12V |
+12 VDC |
D2 |
TDO |
Test Data Output |
D3 |
5V |
+5 VDC |
D4 |
INTP |
|
D5 |
GND |
Ground |
D6 |
CLK |
|
D7 |
GND |
Ground |
D8 |
AD(25) |
Address/Data 25 |
D9 |
GND |
Ground |
D10 |
AD(20) |
Address/Data 20 |
D11 |
GND |
Ground |
D12 |
KEY |
Keyed (no pin) |
D13 |
KEY |
Keyed (no pin) |
D14 |
KEY |
Keyed (no pin) |
D15 |
GND |
Ground |
D16 |
STOP# |
Stop transfer cycle |
D17 |
GND |
Ground |
D18 |
PAR |
Parity for AD0-31 & C/BE0-3 |
D19 |
GND |
Ground |
D20 |
AD(11) |
Address/Data 11 |
D21 |
M66EN |
|
D22 |
AD(6) |
Address/Data 6) |
D23 |
5V |
+5 VDC |
D24 |
AD(0) |
Address/Data 0) |
D25 |
3.3V |
+3.3 VDC |
D26 |
GNT1# |
Grant |
D27 |
GNT2# |
Grant |
D28 |
REQ4# |
Request PCI transfer |
D29 |
GND |
Ground |
D30 |
C/BE(4)# |
Command: Byte Enable |
D31 |
GND |
Ground |
D32 |
AD(58) |
Address/Data 58 |
D33 |
GND |
Ground |
D34 |
AD(51) |
Address/Data 51 |
D35 |
GND |
Ground |
D36 |
AD(44) |
Address/Data 44 |
D37 |
GND |
Ground |
D38 |
AD(37) |
Address/Data 37 |
D39 |
GND |
Ground |
D40 |
REQ5# |
Request PCI transfer |
D41 |
GND |
Ground |
D42 |
REQ6# |
Request PCI transfer |
D43 |
USR |
User Defined |
D44 |
USR |
User Defined |
D45 |
USR |
User Defined |
D46 |
USR |
User Defined |
D47 |
USR |
User Defined |
|
|
|
E1 |
5V |
+5 VDC |
E2 |
TDI |
Test Data Input |
E3 |
INTD# |
Interrupt D |
E4 |
INTS |
|
E5 |
GNT# |
Grant |
E6 |
AD(31) |
Address/Data 31 |
E7 |
AD(27) |
Address/Data 27 |
E8 |
AD(24) |
Address/Data 24 |
E9 |
AD(22) |
Address/Data 22 |
E10 |
AD(19) |
Address/Data 19 |
E11 |
C/BE(2)# |
Command: Byte Enable |
E12 |
KEY |
Keyed (no pin) |
E13 |
KEY |
Keyed (no pin) |
E14 |
KEY |
Keyed (no pin) |
E15 |
TRDY# |
Target Ready |
E16 |
LOCK# |
Lock resource |
E17 |
PERR# |
Parity Error |
E18 |
C/BE(1)# |
Command: Byte Enable |
E19 |
AD(13) |
Address/Data 13 |
E20 |
AD(10) |
Address/Data 10 |
E21 |
C/BE(0)# |
Command: Byte Enable |
E22 |
AD(5) |
Address/Data 5) |
E23 |
AD(2) |
Address/Data 2) |
E24 |
ACK64# |
|
E25 |
5V |
+5 VDC |
E26 |
REQ2# |
Request PCI transfer |
E27 |
REQ3# |
Request PCI transfer |
E28 |
GNT4# |
Grant |
E29 |
C/BE(6)# |
Command: Byte Enable |
E30 |
PAR64 |
|
E31 |
AD(60) |
Address/Data 60 |
E32 |
AD(57) |
Address/Data 57 |
E33 |
AD(53) |
Address/Data 53 |
E34 |
AD(50) |
Address/Data 50 |
E35 |
AD(46) |
Address/Data 46 |
E36 |
AD(43) |
Address/Data 43 |
E37 |
AD(39) |
Address/Data 39 |
E38 |
AD(36) |
Address/Data 36 |
E39 |
AD(32) |
Address/Data 32 |
E40 |
GNT5# |
Grant |
E41 |
BRSV |
Bused Reserved (don't use) |
E42 |
GNT6# |
Grant |
E43 |
USR |
User Defined |
E44 |
USR |
User Defined |
E45 |
USR |
User Defined |
E46 |
USR |
User Defined |
E47 |
USR |
User Defined |
|
|
|
F1 |
GND |
Ground |
F2 |
GND |
Ground |
F3 |
GND |
Ground |
F4 |
GND |
Ground |
F5 |
GND |
Ground |
F6 |
GND |
Ground |
F7 |
GND |
Ground |
F8 |
GND |
Ground |
F9 |
GND |
Ground |
F10 |
GND |
Ground |
F11 |
GND |
Ground |
F12 |
KEY |
Keyed (no pin) |
F13 |
KEY |
Keyed (no pin) |
F14 |
KEY |
Keyed (no pin) |
F15 |
GND |
Ground |
F16 |
GND |
Ground |
F17 |
GND |
Ground |
F18 |
GND |
Ground |
F19 |
GND |
Ground |
F20 |
GND |
Ground |
F21 |
GND |
Ground |
F22 |
GND |
Ground |
F23 |
GND |
Ground |
F24 |
GND |
Ground |
F25 |
GND |
Ground |
F26 |
GND |
Ground |
F27 |
GND |
Ground |
F28 |
GND |
Ground |
F29 |
GND |
Ground |
F30 |
GND |
Ground |
F31 |
GND |
Ground |
F32 |
GND |
Ground |
F33 |
GND |
Ground |
F34 |
GND |
Ground |
F35 |
GND |
Ground |
F36 |
GND |
Ground |
F37 |
GND |
Ground |
F38 |
GND |
Ground |
F39 |
GND |
Ground |
F40 |
GND |
Ground |
F41 |
GND |
Ground |
F42 |
GND |
Ground |
F43 |
GND |
Ground |
F44 |
GND |
Ground |
F45 |
GND |
Ground |
F46 |
GND |
Ground |
F47 |
GND |
Ground |
Contributor: |
Joakim Цgren
|
Информация предоставлена справочником The Hardware Book Team 1996-2004.
- Это интересно
- Я рекомендую
- Поделиться